Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT04339907
NA

Inflammatory Mediators of Glaucoma After Corneal Transplantation (AH-Tears)

Sponsor: Centre hospitalier de l'Université de Montréal (CHUM)

View on ClinicalTrials.gov

Summary

Glaucoma is the most common threat to vision rehabilitation in patients with Boston keratoprosthesis type 1 (KPro) implantation. High intraocular pressure (IOP) is the most important risk factor for glaucoma and may lead to irreversible retinal and optic nerve damage. Glaucoma drainage device (GDD) surgery is used to divert aqueous humor (AH) from the anterior chamber to an external reservoir to regulate flow and decrease the IOP. The AH is in direct communication with any corneal damage or surgery undertaken in the anterior chamber and can serve as a source of potential biomarkers to detect early inflammatory or glaucomatous changes. Tears are also one of the most accessible and non-invasive source of biomarkers, especially in Kpro eyes where the central optic allows communication between aqueous humor and the tears at the surface of the eye. The investigators propose to test the hypothesis that distinct inflammatory mediators in the AH and tears can serve as biomarkers for glaucoma development and progression after CT, making them specifically amenable to targeted treatment strategies to minimize vision loss.

Official title: Uncovering Inflammatory Mediators of Glaucoma Pathogenesis After Corneal Transplantation in Aqueous Humor and Tears

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

200

Start Date

2020-05-11

Completion Date

2029-05

Last Updated

2026-10-23

Healthy Volunteers

Yes

Interventions

OTHER

Sampling of tears

Tears will be collected at the start of any of surgery for which the participant presents. It will be collected using a tear-wash method to allow for protein collection. 0.06 ml of saline solution 0.9% will be instilled on the ocular surface. The participants will turn their eyes with eyes closed. The tear-wash fluid will be collected from the inferior fornix of the eye using a micropipette. Tear-was fluid will be placed in codified tubes stored at -150 degrees.

OTHER

Sampling of aqueous humor

Aqueous humor will be collected at the start of any of surgery for which the participant presents. A paracentesis of the anterior chamber is a common first step in intraocular surgeries. Aqueous humor is then commonly diluted with viscoelastic material injected inside the anterior chamber to avoid collapse of the anterior chamber. This way, the aqueous humor is commonly diluted or replaced entirely by the viscoelastic material injected during intraocular surgeries. A volume of 0.1 ml of aqueous humor will be taken by paracentesis using a 30-gauge needle connected to a 1-ml syringe. It consists of less than half of the total volume of aqueous humor in the eye. Aqueous humor will be placed in codified tubes stored at -80 degrees.

Locations (1)

Centre Hospitalier de l'Université de Montréal (CHUM)

Montreal, Quebec, Canada