Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
COMPLETED
NCT07267143
NA

Does a Highly Filled Injectable Resin Composite Work Better Alone or in Combination With a Nanohybride Resin Composite?

Sponsor: Tolunay Aytas

View on ClinicalTrials.gov

Summary

This is a double blinded, randomized clinical study that evaluated the performance of a high filled injectable resin composite in polydiastema . The polydiastema disorders will be restored with high filled injectable resin composite (G'aenial Injectable Universal ) or anterior composite resin (G-aenial A'chord ). Restorations will be evaluated after 12 months according to FDI criteria and the data will be analyzed.

Official title: Does a Highly Filled Injectable Resin Composite Work Better Alone or in Combination With a Nanohybride Resin Composite? A Randomised Clinical Trial

Key Details

Gender

All

Age Range

18 Years - 35 Years

Study Type

INTERVENTIONAL

Enrollment

45

Start Date

2024-01-01

Completion Date

2026-06-01

Last Updated

2026-11-03

Healthy Volunteers

Yes

Interventions

DEVICE

Nanohybrid Composite (G-ænial A'Chord, GC Corp., Tokyo, Japan)

Conventional nanohybrid resin composite (G-ænial A'Chord, GC Corp., Tokyo, Japan) was used for direct anterior veneer restorations. The material was applied using a free-hand layering technique following digital smile design and wax-up. A transparent silicone index (Exaclear, GC Corp.) was used for shape guidance when necessary. The enamel surfaces were etched with 37% phosphoric acid and bonded with a universal adhesive (G2 Bond, GC Corp.) before composite application. This intervention represents the standard clinical technique for direct composite veneers and serves as the active comparator group.

DEVICE

Highly Filled Injectable Composite (G-ænial Universal Injectable, GC Corp., Tokyo, Japan)

Highly filled flowable injectable composite resin (G-ænial Universal Injectable, GC Corp., Tokyo, Japan) was used either as a sole restorative material or in combination with a nanohybrid composite for direct anterior veneers. For the injection process, a transparent PVS index (Exaclear, GC Corp.) was fabricated from a wax-up model and used to guide the placement of the material. In the combined technique, a 1-mm palatal layer of nanohybrid composite was placed first, followed by the injection of the flowable composite. The procedure aimed to improve adaptation, minimize voids, and optimize esthetic results compared to the conventional layering method.

Locations (1)

Hacettepe University Faculty of Dentistry

Ankara, Turkey (Türkiye)