COMPLETED
NCT07888582
NA

Effectiveness and Safety of the RIGHTEST™ CGM System for Blood Glucose Management in Persons With Diabetes Mellitus

Sponsor: Bionime Corporation

View on ClinicalTrials.gov

Summary

The trial is expected to enroll 50 confirmed cases of type 1 or type 2 diabetes. All eligible subjects must wear a continuous glucose monitoring system on both the left and right upper arms for a maximum of 15 days (360 hours) and adhere to the clinical visit protocol. After enrollment, all subjects will be randomly assigned to either Group A or Group B to determine the time points for clinical visits. All subjects will have venous blood drawn on days 1, days 5 (±1), 10 (±1), and 15 (-1) post-wearing. All subjects will remove all devices on day 15 (-1) based on system prompts and undergo a telephone follow-up on day 4 (±3) thereafter. This clinical trial does not involve long-term follow-up. During the trial, the blood glucose values measured by the "continuous glucose monitoring system" worn by the subjects will be analyzed against the YSI venous blood glucose values measured at the medical institution on days 1, 5 (±1), 10 (±1), and 15 (-1) as control reference values. This analysis aims to evaluate the accuracy, repeatability, stability, high and low blood glucose event alerts, and safety of the continuous glucose monitoring system. Additionally, fingertip blood glucose measurements taken by subjects during home use will be collected to assess the operational feasibility of the continuous glucose monitoring system in a home setting.

Official title: Effectiveness and Safety of the RIGHTEST™ Continuous Glucose Monitoring System for Blood Glucose Management in Persons With Diabetes Mellitus

Key Details

Gender

All

Age Range

18 Years - 80 Years

Study Type

INTERVENTIONAL

Enrollment

50

Start Date

2024-10-09

Completion Date

2024-12-23

Last Updated

2026-10-22

Healthy Volunteers

No

Interventions

DEVICE

RIGHTEST Continuous Glucose Monitoring System

Adults with type 1 or type 2 diabetes mellitus wore two RIGHTEST (HM510) CGM sensors, one on each upper arm, for up to 15 days. Device accuracy was evaluated against venous blood glucose measurements during four in-clinic frequent blood sampling visits.

Locations (1)

Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm

Ulm, Baden-Wurttemberg, Germany