Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07889375
NA

RIGHTEST iFree 2 CGM System for Glycemic Control in Adults With Diabetes Mellitus

Sponsor: Bionime Corporation

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to find out whether using a real-time continuous glucose monitoring (CGM) system can improve daily blood sugar control compared with usual self-monitoring of blood glucose (SMBG; finger-stick testing) in people with diabetes who are treated with insulin. This study will include adults with type 1 or type 2 diabetes who have less-than-ideal blood sugar control while using insulin. The main questions it aims to answer are: * Does CGM-guided diabetes management lead to a larger decrease in HbA1c from baseline to about 6 months than SMBG-guided management? * Does CGM use increase the time that glucose stays in the target range and reduce low blood sugar episodes, without causing new safety problems? Researchers will compare two groups. One group will use the RIGHTEST iFree 2 CGM system together with a smartphone app to view glucose data in real time. The other group will use standard finger-stick blood glucose monitoring with an approved blood glucose meter as their main tool for checking glucose. Both groups will continue to receive routine diabetes care from their usual health-care providers. Participants will take part in regular clinic visits over approximately 6 months. At these visits, study staff will review glucose records, adjust diabetes treatment if needed, and collect information such as HbA1c and other blood tests, device data, and questionnaires about quality of life and diabetes-related distress. Safety information and any device problems will also be recorded. The results will help determine whether CGM can be used as a routine tool to improve long-term blood sugar control in people with diabetes.

Official title: An Open-label, Multicenter, Randomized, Parallel-group Trial to Assess Glycemic Control With the RIGHTEST iFree 2 Continuous Glucose Monitoring System in Adults With Diabetes Mellitus

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

324

Start Date

2026-05-15

Completion Date

2027-03-31

Last Updated

2026-10-26

Healthy Volunteers

No

Conditions

Interventions

DEVICE

Continuous Glucose Monitoring (CGM)

Participants assigned to this arm will use a continuous glucose monitoring (CGM) system as the main tool for day-to-day glucose management. The system consists of a disposable subcutaneous glucose sensor, a reusable transmitter, and the RIGHTEST iFree 2 smartphone application for real-time data display and alerts. Sensors are worn continuously and replaced according to the product labeling over the \~6-month study period. CGM data will be reviewed by participants and study clinicians to guide self-management and diabetes treatment adjustments in addition to usual care.

DEVICE

Self-monitoring of blood glucose (SMBG)

Participants assigned to this arm will use self-monitoring of blood glucose (SMBG) with a capillary finger-stick blood glucose meter as their primary tool for day-to-day diabetes management. An approved meter (e.g., RIGHTEST Max Plus blood glucose meter) and test strips will be provided, together with training on correct use and recording of results. Participants will measure their blood glucose at a frequency consistent with routine diabetes care and the recommendations of their treating physician (for example before meals, at bedtime, and as clinically indicated). SMBG values and downloaded meter records will be reviewed at study visits to guide insulin and other diabetes treatment adjustments. No real-time continuous glucose monitoring data will be used in this arm.

Locations (1)

National Taiwan University Hospital

Taipei, Taiwan