Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07899606
NA

Digital Eye®-Assisted Bone Density Classification and Primary Dental Implant Stability.

Sponsor: King Abdullah University Hospital

View on ClinicalTrials.gov

Summary

Dental implants are used nowadays to replace extracted teeth. They provide a successful substitute for lost teeth. Accurate planning prior to implant placement is very important. Reduced bone density at the site of dental implant placement can affect the success of dental implants. Thus, accurate evaluation of the density is an important aspect in planning. This prospective, single-arm clinical study investigate the clinical applicability of site-specific bone-density assessment and software-recommended drilling in relation to primary implant stability in adults requiring a single implant in a healed premolar or molar site.

Official title: SITE SPECIFIC DRILLING PROTOCOL BASED ON DIGITAL EYE®-ASSISTED BONE DENSITY CLASSIFICATION AND PRIMARY DENTAL IMPLANT STABILITY. SINGLE- ARM PROSPECTIVE CLINICAL STUDY

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

60

Start Date

2025-04-01

Completion Date

2027-01-30

Last Updated

2026-10-27

Healthy Volunteers

No

Interventions

PROCEDURE

R2GATE Digital EYE-Assisted Site-Specific Drilling Protocol

Digitally guided implant placement will be planned and performed for thirty bounded edentulous maxillary and thirty mandibular molar healed sites. Pre-operative CBCT Images of the maxillary and mandibular jaws of the recruited patients will be acquired. Images will be obtained in DICOM format and exported to the software for pre-operative digital implant planning. R2GATE® Digital EYE® is used to assess bone density at the planned implant site and generate a site-specific drilling recommendation. The osteotomy is prepared according to the software-recommended drilling sequence, with the use or omission of an optional final drill recorded when applicable. Primary implant stability is measured immediately after placement using insertion torque and resonance frequency analysis, reported as the implant stability quotient (ISQ). A digitally designed surgical guide is used to guide placement of a MegaGen AnyRidge® dental implant.

DEVICE

R2GATE® Digital EYE® Implant Planning Software

R2GATE® Digital EYE® software is used to assess bone density at the planned implant site and generate a site-specific drilling recommendation. Preoperative CBCT images are imported into the software for digital implant planning. The recommended osteotomy drilling sequence is followed during implant placement.

DEVICE

MEGA ISQ® - Implant Stability Measurement Device

The MEGA ISQ® device is used to assess primary dental implant stability immediately after implant placement using resonance frequency analysis (RFA). Measurements are recorded as implant stability quotient (ISQ) values in the specified measurement directions, and the readings are averaged to obtain the mean ISQ for each implant.

DEVICE

Insertion Torque Measurement

A dental implant surgical motor (MEG Engine® II ) with torque measurement is used during implant placement to record insertion torque, expressed in N·cm, as an indicator of primary implant stability. The insertion torque value is recorded for each implant immediately after placement.

DEVICE

UNC-15 Probe Depth Measurement Device

The UNC-15 Probe is used to assess the clinically achieved implant placement depth. The measured clinical depth is recorded and compared with the digitally planned implant depth to evaluate the accuracy of implant placement and the discrepancy between planned and achieved depths.

Locations (1)

Jordan University of Science and Technology

Irbid, Jordan