Clinical Research Directory
Browse clinical research sites, groups, and studies.
A National, Randomized, Single-blind Study Evaluating the Safety and Efficacy of the TMChM Prosthesis in the Treatment of People With Chronic Flexor Tendon Fingers Injuries Compared to the Prosthesis Used in Clinical Practice
Sponsor: ChM sp. z o.o.
Summary
The objective of the study is to evaluate the safety and effectiveness of the TMChM tendon prosthesis in the treatment of patients with chronic flexor tendon injuries of the fingers, compared with a reference tendon prosthesis currently used in clinical practice. To achieve this objective, finger flexor tendon function will be assessed before and after implantation of either the TMChM tendon prosthesis or the reference prosthesis in patients with chronic flexor tendon injuries of the fingers. The study is designed to demonstrate that the investigational TMChM tendon prosthesis is non-inferior in terms of effectiveness and safety to the prosthesis currently used in clinical practice. The study aims to answer the following questions: * Does the use of the TMChM finger flexor tendon prosthesis result in non-inferior functional outcomes, as assessed by finger tendon function parameters, in patients with chronic flexor tendon injuries compared with the prosthesis currently used in clinical practice? * Can the TMChM tendon prosthesis be safely implanted using the intended surgical technique? The investigational medical device is the TMChM temporary finger flexor tendon prosthesis. The prosthesis incorporates an attachment for the FDS-FDP loop, enabling functional activation of the prosthesis and maintaining tension in the flexor muscles. Additionally, it allows for shaping of the FDS-FDP connection. The patented TMChM temporary finger flexor tendon prosthesis features an attachment located at the proximal end of its silicone core. The prosthesis attachment has a semicircular cross-section, while the core has rounded sides and a rounded distal end. The TMChM prosthesis is intended for implantation during the first stage of surgical treatment of chronic flexor tendon injuries of the fingers. Furthermore, the TMChM prosthesis contains barium sulfate as a radiopaque marker, allowing it to be visualized during X-ray examinations.
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
86
Start Date
2027-04-01
Completion Date
2030-03-31
Last Updated
2026-11-02
Healthy Volunteers
No
Conditions
Interventions
Two-Stage Flexor Tendon Reconstruction with Temporary Tendon Prosthesis Implantation
Chronic finger flexor tendon injuries are treated using a two-stage surgical procedure. During the first stage, the temporary tendon prosthesis is implanted to create a tendon sheath tunnel for subsequent grafting. The damaged tendon remnants are removed, and the pulleys and digital nerves are reconstructed if necessary. The prosthesis is secured distally to the FDP stump and proximally to the FDS-FDP tendon loop. Passive rehabilitation begins after wound healing. After approximately 10-12 weeks, the second procedure is performed. The prosthesis is removed and replaced with a tendon graft harvested from the forearm, which is passed through the newly formed tunnel and fixed to the distal phalanx. The procedure concludes with wound closure and immobilization of the wrist and fingers, followed by controlled postoperative rehabilitation.
Locations (2)
Clinical Department of Orthopedics and Traumatology of the Movement Organ, Medical University of Gdańsk.
Gdansk, Poland
Department of Plastic Surgery and Hand Surgery, Hospital of Święta Jadwiga Śląska in Trzebnica
Trzebnica, Poland