Clinical Research Directory
Browse clinical research sites, groups, and studies.
7 clinical studies listed.
Filters:
Tundra lists 7 Intraocular Lens clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.
This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.
NCT05955846
Evaluation of Safety and Effectiveness of an IOL With a Virtual Aperture Optic
Cataracts are cloudy areas in the lens of the eye that can cause changes in vision. Symptoms of cataracts include cloudy or fuzzy vision and sensitivity to glare. Cataract extraction with Intraocular lens (IOL) implantation is the most commonly performed surgical procedure in the world. Presbyopia affects almost everyone over the age of 50. With age, the natural crystalline lens loses its ability to change shape, or accommodate, to focus on near distances. Thus, individuals with excellent distance vision will still need to wear spectacles for near tasks such as reading, and intermediate tasks such as computer work.
Gender: All
Ages: 40 Years - 75 Years
Updated: 2026-09-18
NCT07769944
Ultrasound Biomicroscopic Assessment of Intraocular Lens Tilt and Decenteration After Phacoemulsification
This study aims to assess intraocular lens (IOL) tilt and decenteration by means of ultrasound biomicroscopy after phacoemulsification.
Gender: All
Ages: Any - 45 Years
Updated: 2026-08-18
1 state
NCT06305338
Predicting Intraocular Lens Tilt Using OCT Measurements and Partial Least Squares Regression Modelling
During cataract surgery an artificial intraocular lens (IOL) is implanted in the eye to replace the lens and to correct the refraction for distance vision. Misalignment of IOLs can cause severe loss of visual quality. Different types of misalignment are known. Tilt, one type of IOL misalignment is thought to play a negative role for the optical performance in eyes with IOL designs, especially, if they have aspheric, toric, or multifocal optics. Various methods to measure IOL misalignments have been described. Studies assessing the IOL position have used subjective grading methods at the slit lamp examination or a Scheimpflug camera to assess IOL decentration and tilt. The subjective grading at the slitlamp may display considerable variability between examiners. This method is more qualitative than quantitative and does not allow fine resolution when reporting IOL tilt. The fact that the patient has no standardized target to focus on makes the method even less reliable. Scanning methods such as Scheimpflug photos require a very well dilated pupil exceeding 6mm to assess the IOL position. Additionally, it can be difficult to identify the anatomical structures of the eye that need to be used as points of reference. Scheimpflug camera images have been used for assessing IOL tilt previously, but erroneous results, often due to corneal magnification, have diminished their widespread use. Another possibility to assess tilt is the use of Purkinje reflexes. The light reflections of Purkinje images at ocular surfaces to evaluate ocular alignment have recently been utilized. Since light is reflected at all interfaces of media with a difference in refractive index, these reflections, called Purkinje images, can be used to assess tilt and decentration of IOLs. Two different clinically applicable Purkinjemeter system provide the measurement of IOL decentration and tilt. The main problem with Purkinje meters is accessibility, as there are only a few prototypes available worldwide. The most recently developed method for tilt quantification is the use of optical coherence tomography (OCT). This method has several advantages compared to the previous methods: OCT based devices are available in most clinics, the resolution of modern OCT devices is high, and the measurements are reproducible. Aim of this study is to measure tilt with two modern OCT based devices and one Scheimpflug camera and to predict the post-operative tilt using partial least squares regression. This method was developed by Wold and introduced to ophthalmology previously.
Gender: All
Ages: 21 Years - Any
Updated: 2026-08-06
1 state
NCT07288086
Reliability and Effectiveness of New Enova Preloaded Intaocular Lens and Cartridge System
Evaluation of the safety and efficacy of the new Enova® preloaded monofocal intraocular lens and cartridge injector system in cataract surgery
Gender: All
Ages: 40 Years - Any
Updated: 2026-03-24
1 state
NCT07317661
Effectiveness of a Large Language Model-Based Educational Tool on Intraocular Lens Options
Patients with cataracts disease need to choose what type of artificial lens will go into their eye prior to surgery date. Some lenses are standard and are usually covered by insurance. Other "premium" lenses have various benefits such as reducing the need for glasses but usually require out-of-pocket costs. The combined busy outpatient clinic and complexity of artificial lens choices in the ever-changing world of cataract surgery tends to lead patients confused about their available lens options. There is an abundance of educational material present in premium lenses, however these are limited by accessibility and are standardized at single educational levels. Therefore in the present study, we want to test whether giving patients a short LLM powered AI-guided explanation from Custom GPT from OpenAI of lens options prior to their consultation with their doctor can improve visit efficiency, physician explanation and patient understanding of lens options. We will compare two groups: standard of care versus standard of care plus AI education. The LLM in this study is intended to provide supplemental information about premium intraocular lens(IOLs) options to study participants, and is no means supposed to replace a health care professional in the diagnosis, cure, treatment, and/or mitigation of disease. Study is analogous to giving a verified health pamphlet to a patient for them to view and learn different IOL options, in other words, facilitating patient understanding of their options. The LLM will be trained by several health care professionals and MD specialists to provide sufficient instructions. Sources will include verified online resources and MD information. The investigators hope to learn if a large language model-based educational tool can improve visit efficiency, physician explanation and patient understanding of intraocular lens options. New knowledge of this study could guide how cataract counseling is delivered in the future and may help clinics spend more time on individualized questions instead of repeating generic information.
Gender: All
Ages: 18 Years - Any
Updated: 2026-01-05
1 state
NCT07276217
Phacoemulsification and Intraocular Lens Implantation: Patient Registry
The aim of the study is to create a patient registry that will allow for comparison of cataract treatment outcomes using phacoemulsification with implantation of different types of intraocular lenses.
Gender: All
Ages: 18 Years - Any
Updated: 2025-12-10
NCT07025707
Comparison of Two Different Methods for Calculating Intraocular Lens Tilt and Decentration
Agreement and Reproducibility of Intraocular Lens Tilt and Decentration Measurements: A Comparison between CASIA2 and CILT
Gender: All
Ages: 21 Years - Any
Updated: 2025-06-17
1 state