Clinical Research Directory
Browse clinical research sites, groups, and studies.
4 clinical studies listed.
Filters:
Tundra lists 4 Osteosynthesis clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.
This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.
NCT07901205
Use of Bioresorbable Magnesium Set Screws in Syndesmotic Injuries: a Pilot Study
The primary aim of this prospective single-center pilot study is to evaluate the implant function of the bioresorbable magnesium set screw (ZX00) for the surgical fixation of the syndesmosis in isolated syndesmotic injuries as well as in bi- and trimalleolar fractures after 12 weeks and 1 year postoperatively. Participants will be routinely operated due to a isolated syndesmotic injury at the department of orthopaedics and trauma. For study purposes patients were asked to complete three questionnaires (NRS, AOFAS, FAAM) at baseline visit, 2, 4, 6, 12 weeks and 12 months follow up. To assess implant integration and resorption kinetics, a CT scan will be performed after 12 weeks and after 1 year.
Gender: All
Ages: 18 Years - 100 Years
Updated: 2026-10-28
1 state
NCT05553028
Study Comparing Arthrodesis Technique of Thoracic and/or Lumbar Spine by Posterior Approach Performed by Robot-assisted Surgery (Robot Mazor X Stealth ™) Versus Conventional Surgery
Osteosynthesis by pedicle screwing is the reference technique since the 1980s, due to the quality of the mechanical grip of the screw in the pedicle, despite difficulties of placing the implant in this narrow tunnel. This precision was improved by fluoroscopy, then by navigation, which made it possible to reduce the extra-pedicular placement of the screws and consequently the complications. Since the 2000s, robotic has been developed in all areas, including medicine and surgery, (Da Vinci robot in urology) and several robots are currently marketed for spinal surgery, Medtronic's Mazor X Stealth ™ robot being the most successful. The aim of this study is to evaluate on a prospective randomized comparative study the quality of the placement of the screws as well as the occurrence of complications, the clinical results and the medico-economic interest that robotic surgery can bring.
Gender: All
Ages: 18 Years - Any
Updated: 2026-04-21
NCT06919770
Use of a Taurolidine Containing Antimicrobial Wash to Reduce Prosthetic Device Infection After Trauma Surgery
A taurolidine-based antimicrobial solution, was evaluated for its safety and efficacy in preventing infections associated with prosthetic materials, such as joint replacements, plates, nails, and screws. This prospective observational study compared Taurolidine to infection rates from scientific literature.
Gender: All
Ages: 18 Years - Any
Updated: 2026-01-20
NCT05960591
Usability of the ADEPTH Sensor for Bore Depth Measurements in Plate Osteosynthesis Procedures
The goal of this monocenter randomized pilot study is to investigate the usability of the ADEPTH sensor for bore depth measurements in plate osteosynthesis procedures. The main question it aims to answer is: \- What is the usability score of the ADEPTH sensor for bore depth measurements during plate osteosynthesis procedures? Participants will receive either bore depth measurements with the ADEPTH sensor or with the manual depth gauge.
Gender: All
Ages: 18 Years - Any
Updated: 2024-04-18
1 state